• MA: Direct thermal decomposition mercury analyzer
  • PE: Fully automated petro-pyrolysis mercury analyzer
  • RA: Reducing-vaporization mercury analyzer
  • WA: Atmospheric mercury analyzer
  • WA-5A
  • WA-5F
  • EMP: Portable mercury survey meter
  • Continuous mercury monitor

[Proffessional point of view] How to select the best mercury analyzer?
[select application/method to] Search the best mercury analyzer

Atmospheric mercury analyzer (AFS)

WA-5F

Atmospheric mercury analyzer that adopts Atomic Fluorescence Spectrometry (AFS) for the detector to achieve ultra-high sensitivity

Contact

WA-5F

Widely complies with overseas official analytical method by adopting CVAFS

The WA-5F adopts atomic fluorescence spectroscopy (AFS) as its detector to ensure measurement with even higher sensitivity (detection lower limit 0.1pg) than its sister equipment WA-5A. This equipment complies with various overseas official analytical methods.

Based on the double-amalgamation method of the previous model, its design was totally renewed. The WA-5F is equipped with not only high-performance options which enable measurement of environment air and various gases (LPG/LNG, flue gas, etc.) in various matrices, but also a newly developed optical system as standard so that it can prevent loss of precious samples, thus, you can measure from low to high concentrations with this equipment of which measurement range is automatically set.

WA-5F

The sample gas is collected into the mercury collector tube, and the tube is placed in the heating furnace of the WA-5F to start measuring. Mercury vaporized due to high temperature heating is scrubbed and dehumidified. Then, the mercury is collected as gold amalgam in the mercury collector tube for re-purification. This tube is re-heated to obtain atomic mercury of which concentration is measured by atomic fluorescence spectroscopy. (*).

Also, you can directly inject the sample using a gas-tight syringe.

(*) Argon gas must be prepared.

Newly developed technology

By adopting newly developed technology, new functions are added to this model.

  • The automatic sample changer dedicated to mercury collector tubes (for 30 samples) makes analysis efficient.
  • By using a new optical system, you can measure from low to high concentrations (up to 1,000ng) with this equipment of which measurement range is automatically set.
  • Ultra-high sensitivity measurement with detection lower limit of 0.1pg is achieved.
  • You can measure samples directly from Tedlar® Bags or from high pressure gas cylinders.

Specfications

Mercury collector furnance partScrubber and DehumidifierElectronic (Peltier) Cooling (optional)
Mercury collector furnanceHeat up to 700°C
Filter (1)Gold filter
Filter (2)Activated carbon filter
PumpDiaphragm Air Pump
Flow rate0.1~1.0L/min (Digital Mass Flow Controller)
Detector partPrincipleAtomic Fluorescence Spectroscopy
Light sourceLow pressure Mercury discharge lamp
Wavelength253.7nm
DetectorsPhoto tube
Carrier GasPurified Argon (99.995% or better)
Detection Limit <0.1pg
Working range0.0001~1000ng
LOW Mode (0~10ng),
HIGH Mode (10ng~1,000ng) selectable
DisplayPeak wave shape, Calibration curve, Measuring condition, Measuring results, Error message etc
CommunicationEthernet
Power supplyAC100~240V±5%, 50/60Hz, 170VA
Installation dimensionsW230 x D460 x H390 (WA-5 unit only)
Weight13 kg (WA-5 unit only)

Applications, Test methods

  ApplicationsAAS Methods
Gas analysisAmbient air, Working environment air, Fuel gas, Natural Gas, Shale Gas, LPG and more.ASTM 6350-98; ISO 6978, ISO 20552, USEPA IO-5
Reduction vaporizationDrinking Water, River water, Sea Water, Waste water, Digested Liquid and more. USEPA 245.7; 1631e; ISO 17825;

Option

Model TC-WA Auto tube changer (30positions)

Model TC-WA Auto tube changer

WA-5A or 5F can be coupled with TC-WA 30-positions tube autosampler. Sampling tubes are set in TC-WA for unmanned fully automated tube desorption, 2nd-amalgamation and measurement on WA-5. Manual direct injection via gas-tight syringe is also possible.

Applications Mercury in Atmospheric Air, Exhaust Gas, Natural Gas, Shale Gas, Hydrocarbon Gas, LPG/LNG, Hydrogen Gas and more
Test methods AAS: ASTM 5954, ISO 6978, ISO 20552, JLPGA-S-07 & etc.
AFS: ASTM 6350, ISO 6978, JLPGA-S-07, ISO 20552, USEPA IO-5 & etc
Heated Vaporizer for LPG Cylinder

Heated Vaporizer for LPG Cylinder (LP-WA)

WA-5A or 5F standalone can be setup to operate with auto-sampling of gaseous hydrocarbon samples from Tedlar Bags input with Gas Volume Meter measuring the sampling volumes. Samples are collected as dual-gold amalgamation before measured on WA-5. Direct injection via gas-tight syringe is also possible.

WA-5A or 5F standalone can be coupled with LP-WA Liquefied Gas Vaporizer to directly collect the compressed gaseous hydrocarbon sample in the cylinder onto the gold-amalgamation sampling tube, with the gas volume measured by a Gas Volume Meter. Collected sample is sequentially auto-desorb to transfer to 2nd-gold amalgamation before measured on WA-5. Direct injection via gas-tight syringe is also possible.

Applications Mercury in Natural Gas, Shale Gas, Hydrocarbon Gas, LPG/LNG, Hydrogen Gas and more
Test methods AAS: ASTM 5954, ISO 6978, JLPGA-S-07 & etc.
AFS: ASTM 6350, ISO 6978, JLPGA-S-07 & etc.
Other Accessories

Mercury Vapor Calibration Box (MB-1), Re-Chargeable Sampling Pump (PS-4)

MB-1
Mercury Vapor Calibration Box
PS-4
Re-Chargeable Sampling Pump

Manual attachment (S-MA), Mercury Collector Tube (M-160)

S-MA
Manual attachment (20mL)
M-160
Mercury Collector Tube

^
^
 